Failure is common, especially on devices that went several years without attention. Rubber discs harden in the Orange County sun, springs weaken and small bits of grit or scale from hard water lodge on a valve seat. Any of these can keep a check from closing tightly.

What matters next is which part failed and whether the body of the assembly is still sound. That decides between a quick rebuild on the same visit and a replacement that may need parts, approval and more time.

Reading a failed result

Result on the reportWhat it meansUsual next step
Check one did not holdThe first check leaks or held below the minimumClean or rebuild check one, retest
Check two leaksThe backup check does not seal against backpressureClean or rebuild check two, retest
Relief valve opened too low or did not openThe RP relief valve is out of rangeRebuild the relief valve, retest
Air inlet did not openA vacuum breaker cannot break a siphonRebuild the canopy and poppet, retest
Shutoff valve will not closeThe tester could not isolate the deviceRepair or replace the shutoff, retest
Could not testDevice buried, damaged or inaccessibleFix access first, then test

From fail to filed

  1. Get the failed readings in writing

    Ask for the numbers, not just the word failed, so you can understand the problem and compare quotes.

  2. Ask for repair options

    Find out whether a repair kit fixes it or whether the body itself is damaged.

  3. Approve a written price

    Repairs are separate from the test fee at many companies. Get the scope and price before work starts.

  4. Repair and retest

    The device should be retested after repair. The final report should show it passing.

  5. Confirm the supplier has it

    Check that both the failed and passing results, or just the final one, were filed as the supplier requires.

Example: a sprinkler PVB fails in spring

Illustrative example. Not a real job or customer.

A Fullerton homeowner's pressure vacuum breaker fails because the air inlet will not open. The tester sees a hardened poppet and a sun-cracked canopy.

  1. The tester shows the owner the readings and the cracked canopy.
  2. The owner approves a written price for a rebuild kit and canopy.
  3. The tester rebuilds the device and runs the test again.
  4. The passing report is filed and the owner keeps a copy.

The device passes on the same visit. The owner adds shade from a nearby shrub to slow future sun damage, without blocking access.

Questions after a failed test

  1. Exactly which component failed, and can I see it?
  2. Is a repair kit still made for this model and size?
  3. Is the body, bonnet or any shutoff valve damaged?
  4. Will you file both the failed and the passing report?

Common questions

Do I have to use the same tester for the repair?

Usually not. You can get another opinion, but ask the city how results from more than one tester should be submitted.

Is my water unsafe after a failed test?

A failed test means the protection is not reliable. Ask the tester whether any use should stop until it is repaired.

Can a device fail right after passing last year?

Yes. Debris, pressure events or damage can cause a failure at any time, which is why testing is repeated.

General information for Fullerton, not a quote or professional advice. In an emergency, call 911.